ReliOn Premier BLU Manual: A Comprehensive Guide
This guide offers detailed instructions for the ReliOn Premier BLU glucose monitor, covering setup, testing, Bluetooth pairing, troubleshooting, and safety precautions – ensuring accurate diabetes care.

The ReliOn Premier BLU is a modern blood glucose monitoring system designed for convenient and effective diabetes management; This device seamlessly integrates Bluetooth technology, allowing for effortless data transfer to compatible mobile devices via the ReliOn Life app. This kit, available at Walmart and Amazon, typically includes everything needed to begin testing – strips, lancets, and a lancing device.
The Premier BLU aims to simplify tracking glucose levels, offering features like memory functions for data review and, in some models, a voice feature for enhanced accessibility. Bilingual user guides (English and Spanish) are often included, supporting a wider user base. Accurate and reliable monitoring is at the core of this system.

Understanding the Kit Contents

The ReliOn Premier BLU kit generally includes a blood glucose meter with Bluetooth capability, essential for modern diabetes management. You’ll find a lancing device to obtain blood samples, alongside accompanying lancets for each test. Crucially, the kit contains test strips – the consumable component for glucose readings.
Often, a small sample of batteries is included to power the meter. Many kits also feature a bilingual user guide (English/Spanish) for broad accessibility, and sometimes a logbook for manual record-keeping. Confirm all components are present before initial use, ensuring a complete and functional diabetes care bundle.
Device Overview: Buttons and Display
The ReliOn Premier BLU meter features a clear, user-friendly design. Typically, a central button navigates menus and confirms actions, crucial for Bluetooth pairing and data review. Left and right arrow buttons allow scrolling through memory and settings. The display shows glucose readings, date, time, and Bluetooth status;
A prominent Bluetooth symbol indicates connectivity. During pairing, “bT” will appear. Error codes are also displayed here. Understanding these buttons and the display’s information is vital for accurate operation and interpreting results, ensuring effective self-monitoring of blood glucose levels.

Setting Up the Meter
Initial setup of the ReliOn Premier BLU involves inserting batteries (refer to the battery information section) and confirming the correct date and time. This ensures accurate record-keeping and data tracking. The meter may prompt you to set these upon first use. Access the settings menu using the center button, then navigate with the arrow buttons to adjust the date and time.
Confirm each selection with the center button. Proper setup is crucial for reliable readings and seamless Bluetooth connectivity with the ReliOn Life app for comprehensive diabetes management.
Initial Setup and Date/Time Configuration
To begin, insert the required batteries into the meter. Upon powering on, the display will likely prompt you to configure the date and time. Use the left and right arrow buttons to navigate and adjust the year, month, day, hour, and minute. Confirm each selection by pressing the central button.
Accurate date and time settings are vital for correct timestamping of blood glucose readings within the meter’s memory and when syncing data via Bluetooth to the ReliOn Life app, ensuring a clear and organized health record.
Bluetooth Pairing with Mobile Devices
The ReliOn Premier BLU seamlessly connects to your smartphone or tablet via Bluetooth, enabling data transfer to the ReliOn Life app for comprehensive tracking and analysis. Ensure Bluetooth is enabled on your mobile device before initiating the pairing process. On the meter, navigate to the Bluetooth settings – typically accessed by pressing the center button.
The meter will display “bT” and initiate a search for available devices. Within the ReliOn Life app, follow the on-screen prompts to pair with your meter, confirming the connection when prompted.
Downloading and Installing the ReliOn Life App
To unlock the full potential of your ReliOn Premier BLU meter, download and install the ReliOn Life app from your device’s app store (available for both iOS and Android). Search for “ReliOn Life” and select the official app developed by ReliOn. Once located, tap “Install” and allow the app to download and install on your mobile device.
After installation, open the app and create an account or log in if you already have one. The app will guide you through initial setup, including permissions for Bluetooth access – essential for pairing with your meter.
Step-by-Step Bluetooth Pairing Instructions
Begin by ensuring Bluetooth is enabled on your smartphone or tablet. On your ReliOn Premier BLU meter, press the center button to enter the Bluetooth settings; the screen will display “bT”. Then, press either the left or right button until “Search” appears. Within the ReliOn Life app, select “Add Device” and then “Search” to locate your meter.
Once found, the app will prompt you to “Continue”. Simultaneously, “Pair” and “YES” will flash on the meter’s display. Press the center button on the meter to confirm pairing and complete the connection.

Performing a Blood Glucose Test

To begin, wash your hands thoroughly. Insert a new test strip into the meter, ensuring correct orientation. The meter will automatically power on. Prepare the lancing device by adjusting the depth setting to suit your skin type. Lance your fingertip with the lancing device, and gently massage to obtain a small blood droplet.
Carefully apply the blood sample to the designated area on the test strip. The meter will display a countdown, and within seconds, your blood glucose reading will appear. Record your results in a logbook or within the ReliOn Life app.
Preparing the Lancing Device
First, remove the cap from the lancing device. Insert a new, sterile lancet firmly into the lancet drum, twisting off the protective cover. Adjust the depth setting dial – lower numbers for thinner skin, higher for thicker. Start with a lower setting and increase if needed to obtain an adequate blood sample.

Pull back the cocking mechanism to prime the device. Ensure the device is loaded correctly before attempting to lance your finger. Always use a new lancet for each test to maintain sterility and minimize discomfort. Replace the cap when not in use.
Applying Blood Sample to the Test Strip
Insert a test strip into the meter, ensuring the correct orientation as indicated on the strip and meter. The meter will power on automatically. Gently squeeze or massage your finger until a small drop of blood forms. Apply the blood sample to the designated area on the test strip – do not smear the blood.
The meter will begin analyzing the sample immediately. Ensure sufficient blood is applied for an accurate reading; insufficient samples may result in an error. Avoid touching the test area of the strip to prevent contamination.
Understanding Test Results
The ReliOn Premier BLU displays your blood glucose level in milligrams per deciliter (mg/dL). Understanding your results requires knowing typical glucose ranges: generally, below 70 mg/dL is considered low, 70-100 mg/dL is normal before meals, and below 140 mg/dL is normal two hours after meals.
The meter stores previous readings, allowing data review to identify trends. Regularly reviewing your results with a healthcare professional is crucial for effective diabetes management and adjusting treatment plans as needed.
Glucose Level Ranges and Interpretation
Interpreting your ReliOn Premier BLU results is vital for diabetes management. Generally, readings below 70 mg/dL indicate hypoglycemia (low blood sugar), requiring immediate attention. Levels between 70-100 mg/dL before meals, and below 140 mg/dL two hours post-meal, are typically considered within a normal range.
Readings consistently above 200 mg/dL suggest hyperglycemia (high blood sugar) and necessitate consultation with your healthcare provider. Individual target ranges may vary; always follow your doctor’s specific recommendations for optimal control.
Memory Functions and Data Review
The ReliOn Premier BLU meter stores your blood glucose readings, allowing for convenient tracking of your health data. You can access previously recorded results directly on the device, reviewing averages over specified periods – typically 7, 14, and 30 days. This feature aids in identifying trends and patterns in your glucose levels.
Furthermore, when paired with the ReliOn Life app via Bluetooth, you can transfer your data for more detailed analysis, charting, and sharing with your healthcare professional, facilitating informed diabetes management decisions.
Using the Voice Feature (If Applicable)
Certain ReliOn Premier BLU models incorporate a voice feature designed to enhance accessibility for visually impaired users. This function audibly announces glucose readings, simplifying the testing process and promoting independence. To activate the voice feature, navigate through the meter’s settings menu using the control buttons.
The voice output clearly states the blood glucose result, eliminating the need to visually interpret the display. Ensure the volume is appropriately adjusted for optimal clarity. Refer to the complete instruction manual for specific voice command options and customization settings.
Maintenance and Care
Proper maintenance ensures the accuracy and longevity of your ReliOn Premier BLU meter. Regularly clean the meter’s exterior with a soft, damp cloth, avoiding harsh chemicals or abrasive cleaners. Disinfect the lancing device after each use with an alcohol swab to prevent infection.
Store test strips in a cool, dry place, tightly sealed in their original container, and avoid exposure to extreme temperatures or humidity. Do not use expired test strips, as they may yield inaccurate results. Handle the meter with care, protecting it from impacts and liquids.
Cleaning and Disinfection Procedures

To maintain hygiene and accuracy, clean your ReliOn Premier BLU meter regularly. Wipe the exterior with a lightly dampened cloth – avoid immersing it in liquid. For disinfection, use a 70% isopropyl alcohol solution on a cloth, gently wiping the meter’s surface.
Always ensure the meter is dry before inserting a test strip. Disinfect the lancing device after every use with a fresh alcohol swab. Never use harsh chemicals or abrasive cleaners, as these can damage the device. Proper cleaning prevents cross-contamination and ensures reliable results.
Test Strip Storage Guidelines
Proper test strip storage is crucial for accurate blood glucose readings. Store ReliOn Premier BLU test strips in their original vial, tightly closed, in a cool, dry place. Avoid direct sunlight and extreme temperatures. Do not refrigerate or freeze the strips, as this can damage them.
Inspect strips before each use; discard any that are damaged, expired, or appear discolored. Once the vial is opened, use strips within three months for optimal performance. Improper storage can lead to inaccurate results, impacting diabetes management.
Troubleshooting Common Issues
Encountering problems with your ReliOn Premier BLU? Common issues include error codes, Bluetooth connectivity problems, and inaccurate readings. Error codes indicate specific malfunctions – consult the manual for their meanings. For connectivity issues, ensure Bluetooth is enabled on both your meter and mobile device, and try re-pairing.
If readings seem inaccurate, verify proper testing technique and strip storage. If problems persist, refer to the FAQ section or contact ReliOn customer support for assistance. Regular maintenance can prevent many issues.
Error Codes and Their Meanings
The ReliOn Premier BLU displays error codes to indicate specific problems. Understanding these codes is crucial for troubleshooting. For example, an “E1” code often signals a strip issue – ensure proper insertion or check expiration. “E2” might indicate insufficient blood sample; retest with a larger drop.
Other codes relate to meter malfunction or internal errors. The user manual provides a comprehensive list of all error codes and their corresponding solutions. Addressing these promptly ensures accurate glucose monitoring and reliable results. Ignoring codes can lead to inaccurate readings.
Connectivity Problems and Solutions
Bluetooth connectivity issues with the ReliOn Premier BLU can hinder data transfer to the ReliOn Life app. First, confirm Bluetooth is enabled on your mobile device. Ensure the meter is in pairing mode – the Bluetooth symbol and “Send” should be flashing. If pairing fails, try restarting both the meter and your phone.
Check for app updates, as outdated versions can cause compatibility problems. Verify the app has necessary permissions (Bluetooth access). If issues persist, deleting and reinstalling the app might resolve the connection. Refer to the manual for detailed troubleshooting steps.

Battery Information
The ReliOn Premier BLU utilizes standard batteries to power its operations. While the specific battery type isn’t always explicitly stated, commonly it requires AAA batteries. Low battery levels are indicated by a warning symbol on the meter’s display. Replace batteries promptly to ensure accurate readings and consistent performance.
Avoid mixing old and new batteries, or different battery types. Always follow proper battery disposal guidelines. Regularly check battery contacts for corrosion and clean if necessary. Consistent battery maintenance is crucial for reliable glucose monitoring.
Battery Type and Replacement
The ReliOn Premier BLU glucose meter typically requires two AAA alkaline batteries for operation. When the low battery indicator appears on the display, it’s time for a replacement. Gently slide open the battery compartment, usually located on the back of the device. Remove the old batteries and insert new ones, ensuring correct polarity (+ and -) as indicated inside the compartment.
Close the battery compartment securely. Using high-quality alkaline batteries is recommended for optimal performance and longevity. Dispose of used batteries responsibly, following local regulations.
Safety Precautions
Always wash your hands thoroughly with soap and water before performing a blood glucose test to prevent infection. Never share the lancing device or lancets with others, as this can transmit bloodborne pathogens. Use only ReliOn Premier BLU test strips, as other strips may yield inaccurate results.
Dispose of used lancets and test strips properly in a sharps container, following local regulations. If you experience any unusual symptoms or concerns, consult your healthcare professional immediately. Keep the meter and supplies out of reach of children.
Warranty Information
The ReliOn Premier BLU Blood Glucose Monitoring System is warranted against defects in materials and workmanship for a period of one year from the date of purchase. This warranty covers the meter itself, but does not include test strips, lancets, or other consumable supplies.
To obtain warranty service, contact ReliOn Customer Service with proof of purchase. Damage caused by misuse, abuse, or unauthorized repairs is not covered. This warranty gives you specific legal rights, and you may have other rights which vary by location.
Frequently Asked Questions (FAQ)
Q: My meter displays an error code. What should I do? A: Refer to the “Troubleshooting Common Issues” section for a list of error codes and their meanings. Q: Can I use test strips from another brand? A: No, only use ReliOn Premier BLU test strips for accurate results.
Q: How often should I calibrate the meter? A: Calibration is not typically required. Q: What if my Bluetooth connection is unstable? A: Ensure Bluetooth is enabled and retry pairing, consulting the connectivity solutions section.
Where to Find Additional Support
Need further assistance with your ReliOn Premier BLU? Contact ReliOn Customer Service for direct support. Their team can address specific questions and concerns regarding your meter’s operation or results. Explore comprehensive online resources, including downloadable manuals and FAQs, available on the official ReliOn website.
Amazon also provides a platform for user reviews and Q&A. ManualsLib hosts digital versions of the user guide. Walmart, as the distributor, may offer support resources as well. These avenues ensure you have access to the information needed for confident self-monitoring.
ReliOn Customer Service Contact Information
For direct assistance with your ReliOn Premier BLU, reaching out to Customer Service is key. While specific contact details aren’t explicitly provided in the readily available online resources, Walmart, as the primary retailer, is the best starting point. Visit the Walmart website and navigate to their customer support section, searching for ReliOn product assistance.
Alternatively, explore the ReliOn website for potential contact forms or phone numbers. Checking Amazon’s product page for the Premier BLU may also yield contact information or links to official support channels. Be prepared to have your meter’s model number handy when contacting support.
Online Resources and Manual Downloads
Numerous online resources support the ReliOn Premier BLU. ManualsLib hosts a Bluetooth pairing guide, offering step-by-step instructions for connecting your meter to mobile devices. Walmart’s website provides access to the ReliOn PREMIER Voice Blood Glucose Monitoring System Instruction Manual, detailing safe usage and cleaning procedures.
Amazon’s product listing often includes links to downloadable user guides in both English and Spanish. Searching “ReliOn Premier BLU manual” on Google will yield additional results, potentially including FAQs and troubleshooting tips. Always verify the source’s legitimacy before downloading any files.